Single-phase grid-connected wind power inverter | ||||||||
Model | LNWG-*KDTL | |||||||
Power (KVA) | 5 | 10 | 15 | 30 | 50 | 75 | 100 | 200 |
Rated Power (KW) | 0-450VDC (☆Other voltages available upon request) | |||||||
MPPT Voltage Range | 100-400Vdc (☆Other voltages can be customized) | |||||||
Rated Input Current (A) | 19.7 | 39.4 | 59.1 | 118.1 | 196.8 | 295.3 | 393.7 | 787.4 |
Maximum Input Current (A) | 21.7 | 43.4 | 65 | 130 | 216.6 | 324.8 | 433.1 | 866.1 |
Rated AC Output Power (kW) | 5 | 10 | 15 | 30 | 50 | 75 | 100 | 200 |
Maximum AC Output Power (kW) | 5.5 | 11 | 16 | 33 | 55 | 82 | 110 | 220 |
Current Harmonic THD | <3% (of rated power) | |||||||
Power Factor | ≥0.99 | |||||||
Maximum Efficiency | High frequency 99%; Power frequency 96% | |||||||
Rated Output Voltage and Frequency | 220Vac 50/60Hz (☆Other voltages and frequencies can be customized) | |||||||
Permissible Grid Voltage Range | ±15% (☆Other voltages can be customized) | |||||||
Permissible Grid Frequency Range | ±10% (☆Other frequencies can be customized) | |||||||
Automatic Operation Conditions | DC input and grid meet requirements, inverter operates automatically | |||||||
Automatic Restart Time After Power Failure | 5 minutes (time can be set) | |||||||
Protection functions | Reverse polarity, short circuit, islanding, overheating, overload, etc. | |||||||
Display method | Touch screen | |||||||
Wind turbine power curve | 30 power points can be set | |||||||
Operating temperature | -10℃~ +50℃ (☆Other temperatures can be customized) | |||||||
Relative humidity | 0-90% (non-condensing) | |||||||
Altitude | Derating required above 2000 meters (1% derating for every 100 meters increase) <6000m | |||||||
Cooling method | Forced air cooling | |||||||
Noise level | <65dB (at 1m distance) | |||||||
Protection class | IP20 (☆Customizable to IP54) | |||||||
Communication protocol | Modbus RTU/ Modbus TCP | |||||||
Three-phase grid-connected wind power inverter | ||||||||
Model | LNWG-*KDTL | |||||||
Power (KVA) | 10 | 30 | 50 | 100 | 250 | 500 | 750 | 1000 |
Rated Power (KW) | 0-800Vdc (☆Other voltages are available upon request, 800-1200V) | |||||||
MPPT Voltage Range | 150-700Vdc (☆Other voltages available upon request: 700-1100V) | |||||||
Rated Input Current (A) | 22.8 | 68.4 | 114 | 228 | 569.8 | 1139.6 | 1709.4 | 2279.1 |
Maximum Input Current (A) | 25.1 | 75.3 | 125.4 | 250.7 | 626.8 | 1253.5 | 1880.3 | 2507 |
Rated AC Output Power (KW) | 10 | 30 | 50 | 100 | 250 | 500 | 750 | 1000 |
Maximum AC Output Power (KW) | 11 | 33 | 55 | 110 | 275 | 550 | 825 | 1100 |
Current Harmonic THD | <3% (of rated power) | |||||||
Power Factor | ≥0.99 | |||||||
Maximum Efficiency | High frequency 99%; Power frequency 96% | |||||||
Rated Output Voltage and Frequency | 380V 50/60Hz (☆Other voltages and frequencies are available upon request) | |||||||
Permissible Grid Voltage Range | ±15% (☆Other voltages can be customized) | |||||||
Permissible Grid Frequency Range | ±10% (☆Other frequencies can be customized) | |||||||
Automatic Operation Conditions | DC input and grid meet requirements, inverter operates automatically | |||||||
Automatic Restart Time After Power Failure | 5 minutes (time can be set) | |||||||
Protection functions | Reverse polarity, short circuit, islanding, overheating, overload, etc. | |||||||
Display method | Touch screen | |||||||
Wind turbine power curve | 30 power points can be set | |||||||
Operating temperature | -10℃~ +50℃ (☆Other temperatures can be customized) | |||||||
Relative humidity | 0-90% (non-condensing) | |||||||
Altitude | Derating required above 2000 meters (1% derating for every 100 meters increase) <6000m | |||||||
Cooling method | Forced air cooling | |||||||
Noise level | <65dB (at 1m distance) | |||||||
Protection class | IP20 (☆Customizable to IP54) | |||||||
Communication protocol | Modbus RTU/ Modbus TCP | |||||||