Product Categories

IPS-HDR-15-12 HDR-15 Series 15w 5v 12v 1a 24v 48v Din Rail Ultra Slim Power Supply for Building Automation
MODEL:IPS-HDR-15-12 Rail Power Supply 12v 15w SPECIFICATION: ① AC input: Single-phase 100-240VAC 50/60hz ② DC output: 12VDC,1.25A ③ Power: 15W ④ Dimension: 17.5*90*54.5MM ⑤ NW: 0.1KG

Features:

1. International universal voltage input range: 85-264VAC/120-370VDC

2. Protection type: Short circuit ,Over current ,Over voltage.

3. Natural air cooling

4. Up to 88% work efficiency

5. Standby power consumption as low as 0.3W

6. 100% full load burn-in test

7. 2-year warranty

 

Electrical specifications

MODEL

HDR-15-5

HDR-15-12

HDR-15-15

HDR-15-24

HDR-15-48

 

 

 

 

OUTPUT

DC VOLTAGE

5V

12V

15V

24V

48V

RATED CURRENT

2.4A

1.25A

1A

0.63A

0.32A

CURRENT RANGE

0-2.4A

0-1.25A

0~1A

0-0.63A

0~0.32A

RATED   POWER

12W

15W

15W

15.2W

15.4W

RIPPLE&NOISE (max)Note.2

80mVp-p

120mNp-P

120mVp-p

150mVpF

240mVp-P

VOLTAGE ADJ.RANGE

4.5-5.5V

10.8~13.8V

13.5~18V

21.6-29V

43.2~55.2V

VOLTAGE TOLERANCE Note.3

±2.0%

±1.0%

±1.0%

±1.0%

±1.0%

LINE REGULATION

±1.0%

±1.0%

±1.0%

±1.0%

±1.0%

LOAD REGULATION

±1.0%

±1.0%

±1.0%

±1.0%

±1.0%

SETUP,RISE TIME

2000ms,80ms/230VAC 2000ms,80ms/115VAC at full load

HOLD UP TIME (Typ.

30ms/230VAC    12ms/115VAC at full load

 

INPUT

VOLTAGE RANGE

85-284VAC (277VAC operational )120~370VDC(390VDC operational )

FREQUENCY    RANGE

47~63Hz

EFFICIENCY  (Typ.

80%

85%

85.5%

86%

87%

AC CURRENT (Typ.

0.5A/115VAC   0.25N230VAC

INRUSH CURRENT (Typ.

COLD START 25A/115VAC    45A/230VAC

 

PROTECTION

OVERLOAD           Note.4

110~145%rated output power

Protection type:Constant current limiting,recovers automatically after fault condition is remove

OVER VOLTAGE

5.75-6.75V

142-16.2V

18.8-22.5V

30-36V

56.5~64.8V

Protection type:Shut off o/p voltage.clamping by zener diode

 

ENWRONMENT

WORKING TEMP.

-30~+70℃(Refer to'Derating Curve’)

WORKING HUMIDITY

20-90%RH non-condensing

STORAGE TEMP,HUMIDITY

40-+85℃,10-95%RH non-condensing

TEMP.COEFFICIENT

±0.03%/C (D-50℃)RH non-condensing

VIBRATION

10~500Hz,2G 10min/1cycle,period for 60min.each along X,Y,Z axes;Mounting:Compliance to IEC60068-2-6

OPERATING ALTITUDE

2000 meters

OVER VOLTAGE CATEGORY

Ⅲ;According to EN61558,EN50178,EN60664-1,EN62477-1;altitude up to 2000 meters

 

 

 

 

 

 

SAFETY&

EMC

(Note  5)

SAFETY STANDARDS

UL60950-1,UL508,TUV EN61558-2-16,IEC60950-1,EAC TP TC 004,BSMI CNS14336-1 approved;Design refer to TUV EN60950-1

WITHSTAND VOLTAGE

UP-O/P:4KVAC

ISOLATION RESISTANCE

VP-O/P:100M Ohms 1500VDC125C170%RH

 

EMC EMISSION

Parameter

Standard

Test Level /Note

Conducted

EN55032(CISPR32),CNS13438

Class B

Radiated

EN55032(CISPR32).CNS13438

Class B

Harmonic Current

EN61000-3-2

Class A

Voltage Flicker

EN61000-3-3


 

 

 

EMCIMMUNITY

EN55024,EN55035,EN61000-6-2,EN61204-3

Parameter

Standard

Test Level /Note

ESD

EN61000-4-2

Level 3,8KV air;Level 2,4KV contact,criteria A

Radiated Susceptibility

EN61000-4-3

Level 3,criteria A

EFT/Burest

EN61000-4-4

Level 3,criteria A

Surge

EN61000-4-5

Level 4.2KVIL-N,criteria A

Conducted

EN61000-4-6

Level 3,criteria  A

Magnetic Field

EN61000-4-8

Level 4.criteria A

Voltage Dips and interruptions

EN61000-4-11

>95%dip 0.5 periods,30%dip 25 periods >95%interruptions 250 periods

OTHERS

MTBF

1166K hrs min,MLHDBK-217F(25℃)

DINENSION

17.5*90*54.5mm  (W*H*D)

PACKING

78g:160pcs/13.5Kg/1.19CUFT