Product Categories

IPS-LNWG400-75K-DTL 75KVA On-Grid Wind Turbine Inverter O Improve Power Generation Economics Improve Grid Stability
①Model: IPS-LNWG400-75K-DTL ②AC INPUT: 1-phase 2-wire 220VAC±15% 50/60HZ±10% or Customize ③DC INPUT:0-450VDC (MPPT voltage range: 100-400VDC, customizable) ④Maximum equipment power: 82KW ; Rated equipment power: 75KW ⑤Application: Small three-phase wind power systems (e.g., village-level wind power stations), distributed three-phase wind power grid connection (or customized for different areas) ⑥Adjusting method: Color touchscreen, switchable between Chinese and English, integrated display and control, and clear display of operating data ⑦Power factor ≥0.99, 30 power curve setting points for maximum power tracking, three-phase balanced output (no phase interference) ⑧Protection features include DC reverse connection protection, DC over/under voltage protection, output overload/overcurrent protection, three-phase voltage imbalance protection, islanding protection, and overheating protection
Datasheet: Download

Single-phase grid-connected wind power inverter

Model

LNWG-*KDTL

Power (KVA)

5

10

15

30

50

75

100

200

Rated Power (KW)

0-450VDC (Other voltages available upon request)

MPPT Voltage Range

100-400Vdc (☆Other voltages can be customized)

Rated Input Current (A)

19.7

39.4

59.1

118.1

196.8

295.3

393.7

787.4

Maximum Input Current (A)

21.7

43.4

65

130

216.6

324.8

433.1

866.1

Rated AC Output Power (kW)

5

10

15

30

50

75

100

200

Maximum AC Output Power (kW)

5.5

11

16

33

55

82

110

220

Current Harmonic THD

<3% (of rated power)

Power Factor

≥0.99

Maximum Efficiency

High frequency 99%; Power frequency 96%

Rated Output Voltage and Frequency

220Vac 50/60Hz (☆Other voltages and frequencies can be customized)

Permissible Grid Voltage Range

±15% (☆Other voltages can be customized)

Permissible Grid Frequency Range

±10% (☆Other frequencies can be customized)

Automatic Operation Conditions

DC input and grid meet requirements, inverter operates automatically

Automatic Restart Time After Power Failure

5 minutes (time can be set)

Protection functions

Reverse polarity, short circuit, islanding, overheating, overload, etc.

Display method

Touch screen

Wind turbine power curve

30 power points can be set

Operating temperature

-10℃~ +50℃ (☆Other temperatures can be customized)

Relative humidity

0-90% (non-condensing)

Altitude

Derating required above 2000 meters (1% derating for every 100 meters increase) <6000m

Cooling method

Forced air cooling

Noise level

<65dB (at 1m distance)

Protection class

IP20 (☆Customizable to IP54)

Communication protocol

Modbus RTU/ Modbus TCP


Three-phase grid-connected wind power inverter

Model

LNWG-*KDTL

Power (KVA)

10

30

50

100

250

500

750

1000

Rated Power (KW)

0-800Vdc (☆Other voltages are available upon request, 800-1200V)

MPPT Voltage Range

150-700Vdc (☆Other voltages available upon request: 700-1100V)

Rated Input Current (A)

22.8

68.4

114

228

569.8

1139.6

1709.4

2279.1

Maximum Input Current (A)

25.1

75.3

125.4

250.7

626.8

1253.5

1880.3

2507

Rated AC Output Power (KW)

10

30

50

100

250

500

750

1000

Maximum AC Output Power (KW)

11

33

55

110

275

550

825

1100

Current Harmonic THD

<3% (of rated power)

Power Factor

≥0.99

Maximum Efficiency

High frequency 99%; Power frequency 96%

Rated Output Voltage and Frequency

380V 50/60Hz (☆Other voltages and frequencies are available upon request)

Permissible Grid Voltage Range

±15% (☆Other voltages can be customized)

Permissible Grid Frequency Range

±10% (☆Other frequencies can be customized)

Automatic Operation Conditions

DC input and grid meet requirements, inverter operates automatically

Automatic Restart Time After Power Failure

5 minutes (time can be set)

Protection functions

Reverse polarity, short circuit, islanding, overheating, overload, etc.

Display method

Touch screen

Wind turbine power curve

30 power points can be set

Operating temperature

-10℃~ +50℃ (☆Other temperatures can be customized)

Relative humidity

0-90% (non-condensing)

Altitude

Derating required above 2000 meters (1% derating for every 100 meters increase) <6000m

Cooling method

Forced air cooling

Noise level

<65dB (at 1m distance)

Protection class

IP20 (☆Customizable to IP54)

Communication protocol

Modbus RTU/ Modbus TCP


WhatsApp
Wechat
Contact Us
Your Name:
Your Email:
Your Message:
This website uses cookies to enhance user experience and to analyze performance and traffic on our website.
We also share information about your use of our site with our social media, advertising and analytics partners.
Do Not Sell My Personal Information
Accept Cookies